Direct Liquid Cooling Cuts Thermal Resistance in Commercial Vehicle Inverters

Published
Author
Aalyia Shaukat
Reads
821

A chip to coolant design cuts thermal layers and modeled mission profile damage, while enabling an oil cooling loop shared with the drivetrain.

Direct Liquid Cooling Cuts Thermal Resistance in Commercial Vehicle Inverters

Removing the ceramic isolation layer from a traction inverter’s thermal path changes more than its cooling performance. Littelfuse’s direct liquid cooling design solders power chips onto a liquid cooled base, with the coolant providing electrical isolation. That shorter path lets oil cool the module while it shares a vehicle’s existing drivetrain loop, and it sharply reduces modeled temperature swing damage under a demanding truck route.

The concept addresses a mismatch between passenger cars and commercial vehicles: trucks are expected to accumulate roughly twice as many inverter operating hours. Dr. Martin Schulz, global principal application engineer at Littelfuse, described the design and its testing in a discussion with Power Electronics News. The prototype uses four 150 A IGBTs, and the team reported carrying 800 A with oil cooling while staying within the devices’ thermal limits.

That result is promising, but it is not yet a field lifetime record. The temperature measurements informed simulations, including a model based on a 700 km truck route through Germany. In that model, direct cooling reduced calculated damage per route run by 97% compared with a conventional module. The next evidence to watch is hardware testing under imposed drivetrain profiles and, if successful, operation in a vehicle on a test track.

Longer service means tighter control of thermal cycling

Commercial vehicle inverters face the same physical cooling problem as passenger car inverters, Schulz said. The difference is the expected duty life. A passenger car inverter may be designed around 8,000 operating hours. A truck, expected to work 10 to 12 hours a day over an extended service life, may need to reach 16,000 hours.

That gap matters because a module that has adequate life margin for a passenger car may wear out much sooner in a truck. Extending life means controlling the stresses that accumulate over repeated operation, and Schulz identified temperature swing as the central concern. Changing chip temperature expands and contracts materials in the module, placing thermomechanical stress on its layers and connections.

The size of each swing matters more than simply counting cycles. Schulz’s account emphasizes that a small number of swings around 80 K can cause more damage than thousands around 10 K. The design problem therefore connects three familiar power electronics aims: efficiency, power density and cooling. Higher efficiency reduces losses; improved cooling carries heat away; both can help reduce damaging temperature excursions.

For a truck inverter, the engineering choice is not simply to increase cooling capacity. The package has to maintain performance across a longer operating life and a varied mission profile. A vehicle cruising at a steady speed on level ground produces relatively stable electrical and thermal conditions. Heavy acceleration, hill climbs, regenerative braking and stop and go driving change demand, with some events producing much larger swings than others.

Fewer layers make a shorter heat path

A conventional power module uses several interfaces between the semiconductor and the coolant. The sequence described by Schulz begins with the chip and solder, continues through the first copper layer, a ceramic substrate and a second copper layer, then another solder joint and the base plate. Thermal interface material attaches that base plate to the cooling system, which transfers heat to the liquid.

The ceramic in the direct bonded copper, or DBC, substrate supplies electrical isolation between the semiconductor and the heat sink. It also adds thermal resistance. The conventional arrangement has about 10 layers in the heat path, counting the chip, attachment materials, substrate, base plate, interface material, cooling surface and liquid boundary. Each boundary adds resistance between the heat generating device and the coolant.

In the direct cooled structure, the chip is soldered directly onto the heat sink. Schulz described the path as three layers. The ceramic substrate and the conventional base plate and interface stack are removed. Heat can move from the semiconductor to the cooling liquid through a much shorter route.

Figure 1: Conventional module and direct cooling comparison. In the direct cooled design, the chip is soldered onto the liquid cooled base. Source: Littelfuse.

That change shifts the isolation task. In a conventional module, the ceramic keeps the heat sink electrically separated from the active semiconductor. With direct cooling, the cooling block can be electrically active, so the coolant must be electrically resistive enough to prevent unwanted current paths. The design retains the need to isolate electrical parts from accessible surfaces, but assigns that function to the liquid rather than the ceramic substrate.

This is the key trade off: removing a material that is useful for electrical isolation, but also impedes heat flow, improves the thermal path while making coolant properties and system layout central to electrical safety. Schulz discussed residual current detection as one way to monitor unwanted current through the liquid. He said that with oil, a conductivity level high enough to create concern would likely signal more serious contamination problems as well.

Oil can make the system simpler

The team considered two coolant options: a deionized water glycol mixture and oil. Water glycol transfers heat more effectively, but it must remain deionized to preserve its electrical properties. Contamination can increase conductivity, so the loop needs filtration. Schulz said the filters used to maintain deionized coolant cannot be regenerated; they must be removed and replaced, adding service work, replacement cost and downtime.

Oil extracts heat less effectively than water glycol, but it is electrically nonconductive by design. Schulz said simple filtration can address contamination while the oil remains nonconductive, even when contamination is substantial. The improved thermal transfer of the direct cooled structure is what makes the lower heat extraction performance of oil workable for the inverter.

Commercial vehicles already use oil to cool mechanical components such as the gearbox and motors. If the inverter can use that same oil, the vehicle can avoid a separate coolant loop with its own pump, tubing and radiator. Schulz called this a “single oil solution.” The practical appeal is system integration: one loop can serve both the power electronics and drivetrain, reducing the number of cooling components and the complexity associated with a second fluid system.

Water glycol may still make sense where a vehicle already has a deionized cooling loop. Schulz pointed to hydrogen fuel cell trucks, which need deionized coolant for the fuel cell. In that case, using the same type of fluid for the inverter could fit the vehicle architecture. But the coolant choice also affects tubing and pump design.

At a flow demand of 20 or 30 liters per minute, the tube diameter and possible coolant contamination affect the electrical resistance of the loop. Schulz said Littelfuse’s analysis indicated that roughly 6 to 8 meters of tubing would be needed to meet the resistance requirement discussed for functional safety. An alternative would be a pump without metal parts, such as a ceramic pump, which he described as expensive.

For a battery electric truck without an existing deionized loop, oil may therefore simplify the system. Schulz described a possible arrangement with one pump, radiator and monitoring system. The trade is straightforward: water glycol offers somewhat better heat transfer, while oil can fit an existing drivetrain loop and avoid the maintenance demands of preserving deionization.

Infrared imaging showed thermal headroom

Littelfuse used infrared imaging to examine heat distribution across the module. A thermocouple or point sensor reports temperature at one location. An infrared camera captures a two dimensional view, allowing the team to examine chip temperature gradients and how heat spreads. Schulz said this was useful for steady state measurements, where the researchers wanted to see both the temperature and its distribution.

Preparing the component for imaging required an exposed surface. The soft gel often used over power semiconductors blocks infrared radiation, even when it appears transparent to visible light. The test setup therefore used a component without that gel and applied a spray coating to create a suitable surface for infrared measurement. The team then applied current, producing losses and heat that the camera could map.

The results showed that the cooling was effective enough to keep the chips relatively cool at their rated current. A 150 A rating is tied to a temperature condition: in the conventional reference case described by Schulz, the chip is rated for 150 A with a case temperature of 80 °C and junction temperature of 150 °C. In the direct cooled module, the liquid cooled base is close to the chip, separated by about 2 mm of copper.

With oil cooling, the team said an individual chip rated at 150 A could carry about 250 A while remaining within its 175 °C junction temperature limit. The prototype had four 150 A IGBTs in parallel, giving it a nominal total rating of 600 A. Littelfuse reported that it could carry 800 A within thermal limits using oil.

The team also compared modeled junction temperatures under the same conditions. The conventional liquid cooled module reached about 150 °C. The direct cooled module reached about 60 °C with oil and about 55 °C with water glycol. Those figures come from simulation based on measurement data; they should be read as a comparison under the stated modeled conditions, rather than as a universal operating temperature for every inverter installation.

Figure 2: Power cycling lifetime plotted against temperature swing. Littelfuse’s estimate moves from roughly 100,000 cycles for a typical module into the tens of millions with direct cooling. Source: Littelfuse.

Route data links cooling to estimated lifetime

To estimate the lifetime effect, Littelfuse used a driving profile recorded on a truck traveling through Germany. The company combined the route data with laboratory measurements of losses, forward characteristics and heat development. Those inputs allowed the team to simulate how chip temperature would rise and fall as the truck moved through the route.

The severe swings came primarily from demanding climbs. A fully loaded 40 ton truck can descend into a valley with its semiconductors cooled, then demand high torque and current to climb the next slope. Schulz said ordinary city acceleration and low speed driving did not produce the same temperature swings. Long climbs, including sections in the Kassel Hills and steeper terrain in southern Germany, made the route particularly demanding.

The 700 km route ran north to south and back through Germany. Schulz said it included slopes in the range of 8% to 12% for kilometers in the Kassel area. He described the route as severe, though not necessarily a complete worst case for every truck duty cycle.

The team calculated a damage factor for each temperature cycle and compared the direct cooled design with a conventional module that included DBC. In the model, the direct cooled design incurred 97% less damage over one run of the route. Schulz translated that result into an estimated lifetime improvement of about 30 times: the same load profile would need to be repeated roughly 33 times to produce the damage assigned to one run with the conventional design.

The power cycling curve illustrates why the temperature reduction matters. Schulz said that about 20 K less temperature swing can double the number of cycles. An 80 K reduction therefore maps to a much larger cycle count in the curve, moving from a conventional reference near 100,000 cycles to tens of millions. The exact service life still depends on actual duty, module construction and conditions; the curve supports a comparative estimate rather than a field guarantee.

Electrical tests and packaging questions

Littelfuse also performed double pulse testing to examine the device’s switching behavior. The laboratory setup used a half bridge: the high side provided the freewheeling diode path for an inductive load, while the low side was the device under test. The gate driver was connected with coaxial wire to keep inductance in the gate path low. A pulse raised current through the inductive load, letting engineers examine behavior at chosen voltages, currents and temperatures.

The prototype showed relatively high internal stray inductance, which Schulz attributed to the quick prototype construction. He said it was manageable: the team reached 800 A at 800 V, a range relevant to truck applications. A full inverter was planned for testing shortly after the interview. That work would provide evidence beyond the single switch and half bridge tests.

The cooling block’s electrical status also affects inverter layout. Schulz clarified that the module itself acts as the cooler; a separate thick aluminum carrier is not required to mount modules. The assembly could be mounted on an insulated plate, and the gate drive can be built onto a small printed circuit board in a familiar arrangement. Littelfuse had built a board containing the gate drive unit and reported that it worked.

Common mode current through the coolant and hoses remains a design question. Schulz did not claim that such current is absent. In a conventional module, the DBC ceramic and copper can form capacitive coupling to a grounded heat sink. The direct cooled structure removes that same layered capacitor arrangement, so he expected the coupling and common mode issue to be smaller. The design discussed also used Y capacitors at the inverter output, following a typical approach.

Device choices, topologies and applications

The prototype uses IGBTs for practical reasons. The lead customer requested them, and the selected devices were available in a form compatible with Littelfuse’s clip and tab interconnection. That approach requires copper pieces to be attached to the chip’s top surface, while many power chips are designed for aluminum wire bonding rather than soldered top side connections.

Schulz said the cooling structure itself can support different power semiconductor types. He expects IGBTs, silicon MOSFETs and silicon carbide MOSFETs to be candidates. Gallium nitride devices present additional challenges: customers are asking for voltages above 1,200 V, which Schulz said were not then available in GaN parts, and their faster switching makes low stray inductance more important. Simply substituting a GaN device into the prototype would not work. Littelfuse was working on other direct cooling structures intended to reduce stray inductance and support silicon carbide.

The topology is not the main constraint. A single switch can be assembled into different circuits, but the connections add stray inductance. A half bridge is a likely building block for a three phase six pack. The cooling plumbing then becomes a packaging consideration: separate half bridges could mean six coolant connections for a six pack, while integrating the devices into one block could reduce that to one inlet and one outlet, albeit with larger tubes.

Other arrangements include six packs with brake choppers and 12 pack configurations for switched reluctance machines. Those machines use three pairs of high and low side switches arranged as choppers. Schulz said the direct cooling method could accommodate these circuits; the engineering task is choosing which building blocks can be combined in a housing with practical coolant routing.

Traction inverters were the entry point, but the heat transfer approach may fit other high power equipment where liquid cooling is already part of the system. Schulz named inductive heating for metal processing, welding, electrolysis, wind power, high power solar and solid state transformers. Oil cooling in solid state transformers makes them an especially direct match. He also raised the possibility of using the structure with older device types, including bipolar diodes, thyristors, GTOs and IGCTs, where their established roles in equipment such as megawatt motor soft starters remain useful.

The results so far point to a clear engineering benefit: a shorter thermal path can create headroom for oil cooling, reduce temperature swing and potentially simplify the vehicle’s cooling architecture. The durability estimate is based on measured component data and a simulated route, so hardware in the loop and vehicle testing will determine how well that advantage carries into real operation. For inverter designers, the central question is now how to capture the thermal gain while managing coolant isolation, electrical parasitics and practical module plumbing.

Source: Aalyia Shaukat · www.powerelectronicsnews.com