TI TPS563200EVM-652 Holds a 1.05 V Output Across a 5 V to 15 V Input Sweep
- Published
- Author
- Aalyia Shaukat
- Reads
- 982
No-load bench measurements show the TPS563200EVM-652 output rising just 3 mV as its input increases from 5 V to 15 V.


For a low-voltage digital rail, a supply’s input range matters only if the output stays within its required range as that input changes. On the Texas Instruments TPS563200EVM-652 evaluation module, a no-load bench sweep from 5 V to 15 V produced output readings between 1.060 V and 1.063 V. That 3 mV change is a useful first look at line regulation, though it doesn't establish performance under load or across other operating conditions.
The board is built around the TPS563200 synchronous buck converter. Its specified input range is 4.5 to 17 V, and the evaluation board’s feedback network sets a nominal output of approximately 1.05 V. The converter integrates high-side and low-side switching MOSFETs, runs at 650 kHz, and uses TI’s D-CAP2 control method.
What sets the output voltage
A buck converter reduces voltage by switching the input onto an inductor, then using the inductor and output capacitors to deliver a smoother DC rail. In this board, the integrated MOSFETs control the current path through a 1.5 µH power inductor. The high-side MOSFET applies energy from the input; the low-side MOSFET provides the synchronous current path during the remainder of the switching cycle.

Three output capacitors, C5, C6, and C7, are each rated at a nominal 22 µF, for 66 µF total. Together with the inductor, they smooth the switched waveform. The capacitors also supply or absorb energy during brief changes at the output while the control loop responds.
The feedback divider tells the control circuitry what output voltage the board is producing. Here, R1 is 3.74 kΩ and R2 is 10 kΩ, setting the output to roughly 1.05 V. The board’s output can be configured from 1 V to 6.5 V by changing R1, as shown in the component reference.

JP1 controls the converter’s enable input. The board can remain connected to its input supply while JP1 holds enable at ground; moving the jumper to connect enable to Vin turns on the regulator. This gives the bench test a simple way to power the board first and then activate its output.
Bench check at 5 V
The first measurement checked whether the board produced its configured rail from a 5 V input. A bench supply connected to J1 provided input voltage and ground, and a digital multimeter measured the output at J2. No external load was connected.
With the supply set to 5 V in constant-voltage mode, JP1 was initially set to disable the converter. Once the input was stable, the jumper was moved to the enable-to-Vin position. The meter then read approximately 1.060 V, close to the board’s nominal 1.05 V setting.
That small offset is consistent with the limits of a real circuit and measurement setup: component tolerances, regulator accuracy, and meter accuracy all affect the observed value. The reading confirms basic step-down operation at this input, but a single no-load measurement doesn't characterize the rail’s behavior when a circuit draws current.
Output during the input sweep
For the second check, the wiring, enable state, and no-load condition were kept the same while the input was changed. The measured results were:
| Vin | Measured Vout |
| 5 V | 1.060 V |
| 8 V | 1.061 V |
| 12 V | 1.062 V |
| 15 V | 1.063 V |
Measured output voltage across the input voltage sweep (Source: Abhishek Jadhav, Power Electronics News)
Across the 5 V to 15 V range, the output rose by 3 mV. Relative to the nominal 1.05 V setting, that difference is approximately 0.3%. The readings indicate that the feedback loop kept the output close to its target as the input tripled within the tested range.
The control loop explains the trend. As input voltage rises, the converter needs a smaller fraction of each switching cycle to transfer the energy required by the output. Feedback allows the TPS563200 to adjust switching operation in response, countering input changes at the regulated rail. The slight upward movement in the readings remains visible, so the test shows close regulation rather than a perfectly unchanged output.
What the measurements establish
This is a focused demonstration of conversion and no-load line regulation. It shows that the TPS563200EVM-652 produced about 1.060 V from a 5 V input and that its output reading changed by only 3 mV as the input reached 15 V. The sweep stays within the converter’s stated 4.5 to 17 V input range.
For an engineer selecting or integrating the module, the practical next step is to characterize the conditions this test leaves open: output behavior under load, efficiency, ripple, response to rapid load changes, and thermal performance. Those measurements would show how the rail behaves in an operating system, where the load and temperature can change along with the input.